Difference between measuring resistance and conductivity

September 11, 2020 By David Herres Leave a Comment

Generally, an electrical conductor is a long solid rod, often insulated. It may be rectangular, like the electrician’s bus bar, irregular in cross section, or it may be merely a conductive path through the atmosphere, created by a process of ionization.

Most electronics professionals have measured the resistance of conductors typically using a volt-ohm meter. Most electrical conductors today are copper alloys. Aluminum is used for conductors in utility-scale installations where in such quantities copper becomes excessively costly. Aluminum has lower conductivity than copper. The electrical resistivity for copper is 1.724×10-8 Ω-m (0.0174 μΩ-m) and electrical resistivity for aluminum is 2.65×10-8 Ω-m (0.0265 μΩ-m), but is not really a problem when the wires can have a large diameter.

Electrical codes require aluminum conductors be used in larger sizes relative to copper when handling comparable ampacity. But aluminum conductors are problematic in regard to their terminations because the metal has a tendency to creep. More specifically, copper has a lower coefficient of thermal expansion. What this means is that unlike copper, a tight pressure connection on an aluminum conductor may loosen after about a year, causing the joint to heat up when electrically loaded. This loosening encourages the formation of corrosion with more heat and eventual equipment failure or electrical fire. The remedy is, during installation, to wire-brush and to apply corrosion inhibitor (composed of zinc powder mixed with polybutene) to mating surfaces and also to accurately torque all pressure joints.

In the 1960s and 1970s, aluminum wire was widely used in residential installations because of a spike in the price of copper, but aluminum use indoors fell into disfavor because of the many fires. Two factors came into play. First, aluminum terminations are far more problematic in small sizes. And second, with hundreds and sometimes thousands of terminations in a residential installation, the chance of error is great. (It takes only one bad connection to cause a fire.)

However, electrical conductors aren’t the only entities where resistance to current flow is an important parameter. There are many applications in agriculture, water quality, pharmaceutical processing, and other areas where the conductivity of liquids is important. Ordinary volt-ohm meters can give a rough idea of conductivity (the reciprocal of resistivity) in these applications if they have a sufficiently high resolution, but the usual approach is to use a specialized conductivity meter.

Of course, water is a poor electrical conductor. Distilled water is an extremely poor electrical conductor. The reason is substances (or salts) dissolved in the water determine its degree of conductivity. With more dissolved ions, the solution can carry more electrical charge.

A conductivity meter reports conductance as the inverse of a resistivity measurement. Material resistivity is reported as bulk or volume resistivity in ohms/cm, so conductivity is measured in mhos/cm and defined as Siemens/m (S/m).

hanna HI 4321
Visible in this image of a Hanna Instruments HI 4321 is an amperometric probe, held in place by a positioning arm. This research-grade EC/Resistivity/TDS/Salinity benchtop meter is capable of millesimal measuring resolution of conductivity with an extended range from 0.001 µS/cm to 1 S/cm.

A conductivity meter typically has a probe with two closely spaced electrodes (usually 1 cm apart). This is called an amperometric probe. As with an ordinary DVM, the meter applies a known voltage to the electrodes and measures the current in the solution. Current is proportional with the conductivity. The probe pins themselves can be either graphite or stainless steel.

One difficulty with the amperometric technique is that the resistance can be precisely gauged but isn’t constant. Effects such as deposits on the electrodes and polarization because of electrolysis can make measurements drift. For low to medium levels of conductivity (< 2 mS/cm) the effect is not significant. For higher values the usual approach is to use a potentiometric probe.

toroidal sensors
Toridal conductivity sensors, these from M4 Knick.

The potentiometric method employs four rings: two outer rings apply an ac voltage and induce a current loop in the solution. The remaining inner rings measure the voltage drop induced by the current loop. The voltage drop measured directly depends on solution conductivity.

Potentiometric probes can be used in solutions where the electrolysis effect makes amperometric methods impractical. The rings are generally stainless steel or platinum depending on to what degree the rings must resist corrosion and cleaning.

Another method of conductivity measurement employs an inductive or toroidal sensor. The advantage of this technology is that measurement takes place without any electrical contact between the electrode and the process fluid. The probe uses two toroidal transformers which are inductively coupled side-by-side and encased in a plastic sheath. A high-frequency reference voltage gets fed to the first toroid or drive coil which generates a strong magnetic field. Conductive ions in the liquid close the magnetic field and induce a current in the second toroid.

Hach HQD
An advanced digital handheld portable meter from Hach, part of the HQD series, for water testing pH, conductivity, TDS, salinity, dissolved oxygen (DO), and other measurements.

Conductivity meters frequently find use where there’s a need to measure the amount of totally dissolved solids in a solution because conductivity can be a function of dissolved solids. Conductivity meters frequently find use in agriculture to measure the salinity levels of surface water and of soil samples. Conductivity meters designed for such applications sometimes also can gauge other parameters such as pH and dissolved oxygen.

Another interesting application for conductivity meters is the measurement of plant damage. When plants are stressed there is typically damage to their cellular membranes. Electrolytes leak from the cells of stressed tissues. Using a conductivity meter to quantify this leakage gives an indication of the plant’s stress severity.

 

You may also like:

  • Square Span 20
    Differences between stand-alone and scope-based spectrum analyzers
  • ammeter setup
    How to measure current and energy use accurately
  • PCIM
    Gallery: Interesting instruments on display at PCIM Europe

  • User review: Connecting the Tektronix AFG 31000 AWG to the…

  • The difference between histograms and spectrograms

Filed Under: FAQ, Featured, Meters & Testers, New Articles Tagged With: FAQ, Hach, Hannainstruments, m4knick

Reader Interactions

Leave a Reply Cancel reply

You must be logged in to post a comment.

Primary Sidebar

Current Digital Issue

A frequency you can count on There are few constants in life, but what few there are might include death, taxes, and a U.S. grid frequency that doesn’t vary by more than ±0.5 Hz. However, the certainty of the grid frequency is coming into question, thanks to the rising percentage of renewable energy sources that…

Digital Edition Back Issues

Oscilloscopes Finder

Search Millions of Parts from Thousands of Suppliers.

Search Now!
design fast globle

Subscribe to our Newsletter

Subscribe to test and measurement industry news, new oscilloscope product innovations and more.

Subscribe Today

EE TRAINING CENTER CLASSROOMS

EE Classrooms

RSS Current EDABoard.com discussions

  • Measuring a 1GHZ Signal
  • Extract spice netlist from Prime Time
  • Requests to Deactivate/Delete EDABoard User Account
  • Need help in finding distributor having components
  • transient vs. pss simulation

RSS Current Electro-Tech-Online.com Discussions

  • Is there a discord for this forum?
  • 2nd pcb design program?
  • How to power up two stereo audio amplifiers from a single source of power supply
  • Need help for diy ups project
  • cadence transient and pss simulation

Footer

EE World Online Network

  • DesignFast
  • EE World Online
  • EDABoard
  • Electro-Tech Online
  • Analog IC Tips
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips
  • Connector Tips
  • Wire and Cable Tips
  • 5G Technology World

Test & Measurement Tips

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us
Follow us on TwitterAdd us on FacebookFollow us on YouTube Follow us on Instagram

Copyright © 2022 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy