• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
  • Advertise
  • Subscribe

Test & Measurement Tips

Oscilloscopes, electronics engineering industry news, how-to EE articles and electronics resources

  • Oscilloscopes
    • Analog Oscilloscope
    • Digital Oscilloscope
    • Handheld Oscilloscope
    • Mixed-signal Oscilloscope
    • PC-based Oscilloscopes – PCO
  • Design
  • Calibration
  • Meters & Testers
  • Test Equipment
  • Learn
    • eBooks/Tech Tips
    • FAQs
    • EE Training Days
    • Learning Center
    • Tech Toolboxes
    • Webinars & Digital Events
  • Video
    • EE Videos
    • Teardown Videos
  • Resources
    • Design Guide Library
    • Digital Issues
    • Engineering Diversity & Inclusion
    • Leap Awards
    • White Papers
  • Subscribe
You are here: Home / Test and Measurement News / Isolated LXI thermocouple and voltage measurement instrument sports 24-bit ADC for each of 16 channels

Isolated LXI thermocouple and voltage measurement instrument sports 24-bit ADC for each of 16 channels

June 1, 2017 By Taylor Meade Leave a Comment

AMETEK VTI Instruments announced today the introduction of its latest LXI instrument, the EX1401 a precision, 16-channel, isolated thermocouple and voltage measurement instrument.

The EX1401 delivers accuracies of ±0.20°C with 1000 V channel-channel isolation, builtin self-test capabilities, and independent 24-bit ADC’s per channel. Independent Cold Junction Compensation (CJC) — implemented on a per channel basis — and Open Thermocouple Detection (OTD) further enhance the instrument’s capabilities.

Unlike other thermocouple and voltage measurement instruments, the EX1401 offers Power over Ethernet+ (PoE+) and flexible DC power options for portable applications. With PoE+, the test engineer does not need to connect both data and power cables. The engineer simply places the instrument anywhere in a test chamber, or around the test article, and connects it to the network.

With the ability to acquire data at 20K samples/second/channel, the EX1401 can be deployed in situations that demand rapid responses to quickly changing conditions, including high-speed temperature transient applications. The EX1401 has application in automotive and battery testing; highly accelerated life test/ highly accelerated stress screening (HALT/HASS); health monitoring; and jet engine testing. It can be used in any test environment that requires accurate temperature measurement and repeatability.

An industry-standard LXI interface allows the EX1401 to be distributed and positioned close to the device-under-test, reducing the implementation and support costs associated with long cable lengths. That also reduces transducer cable lengths and associated coupled EMI interference, helping improve measurement accuracy. In addition, the instrument features a comprehensive, built-in self-test function that reports instrument status and problems, maximizing run-time performance.

A full-featured embedded web interface provides configuration and data displays, simplifying setup and usage. EXLab Express, VTI’s intuitive data acquisition software, is included with each instrument, eliminating the need for programming.

Parallel data storage and standalone autonomous operating modes further expand the utility of this versatile instrument. The EX1401 also supports IEEE 1588 Precision Time Protocol (PTP), allowing engineers to synchronize measurements from many devices throughout the test application.

Features at a Glance

  • Typical accuracies of ±0.20°C
  • 16-channel isolated universal thermocouple/voltage inputs
  • Power over Ethernet+ (PoE+)
  • 20K samples/second/channel sample rate
  • 24-bit ADC per channel
  • 500 V channel-ground isolation
  • 1000 V channel-channel isolation
  • Data logger acquisition mode
  • Built-in parallel data streaming
  • Full-featured embedded web interface
  • LXI Ethernet interface
  • 8-bit bank isolated digital I/O
  • Compact 1U half-rack form factor

AMETEK VTI Instruments

www.vtiinstruments.com

Filed Under: Test and Measurement News Tagged With: vtiinstruments

Reader Interactions

Leave a Reply Cancel reply

You must be logged in to post a comment.

Primary Sidebar

Featured Contributions

impedance plot

How physics relates signal integrity, power integrity, and EMC

Why engineers need IC ESD and TLP data

Verify, test, and troubleshoot 5G Wi-Fi FWA gateways

How to build and manage a top-notch test team

How to use remote sensing for DC programmable power supplies

More Featured Contributions

EE TECH TOOLBOX

“ee
Tech Toolbox: Sensors
In this Tech Toolbox, we cover some of those technologies driving the next generation of connected systems, including ultra-low-power sensing strategies that extend node battery life, and 60 GHz CMOS radar for contactless health and presence detection.

EE TRAINING CENTER

EE Learning Center
“test
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for EE professionals.
bills blog

RSS Current Electro-Tech-Online.com Discussions

  • reviving old swordfish program but?
  • Assistance locating a 'trail' camera gadget, please ?
  • Analog multiplexer has gone obselete
  • Difference between TTL, RS232 and RS485
  • Smart Buoy project

Footer

EE World Online Network

  • 5G Technology World
  • EE World Online
  • Engineers Garage
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • EDA Board Forums
  • Electro Tech Online Forums
  • EV Engineering
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips

Test & Measurement Tips

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us

Copyright © 2026 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy