• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
  • Advertise
  • Subscribe

Test & Measurement Tips

Oscilloscopes, electronics engineering industry news, how-to EE articles and electronics resources

  • Oscilloscopes
    • Analog Oscilloscope
    • Digital Oscilloscope
    • Handheld Oscilloscope
    • Mixed-signal Oscilloscope
    • PC-based Oscilloscopes – PCO
  • Design
  • Calibration
  • Meters & Testers
  • Test Equipment
  • Learn
    • eBooks/Tech Tips
    • FAQs
    • EE Training Days
    • Learning Center
    • Tech Toolboxes
    • Webinars & Digital Events
  • Video
    • EE Videos
    • Teardown Videos
  • Resources
    • Design Guide Library
    • Digital Issues
    • Engineering Diversity & Inclusion
    • Leap Awards
    • White Papers
  • Subscribe
You are here: Home / Test and Measurement News / Isolated LXI thermocouple and voltage measurement instrument sports 24-bit ADC for each of 16 channels

Isolated LXI thermocouple and voltage measurement instrument sports 24-bit ADC for each of 16 channels

June 1, 2017 By Taylor Meade Leave a Comment

AMETEK VTI Instruments announced today the introduction of its latest LXI instrument, the EX1401 a precision, 16-channel, isolated thermocouple and voltage measurement instrument.

The EX1401 delivers accuracies of ±0.20°C with 1000 V channel-channel isolation, builtin self-test capabilities, and independent 24-bit ADC’s per channel. Independent Cold Junction Compensation (CJC) — implemented on a per channel basis — and Open Thermocouple Detection (OTD) further enhance the instrument’s capabilities.

Unlike other thermocouple and voltage measurement instruments, the EX1401 offers Power over Ethernet+ (PoE+) and flexible DC power options for portable applications. With PoE+, the test engineer does not need to connect both data and power cables. The engineer simply places the instrument anywhere in a test chamber, or around the test article, and connects it to the network.

With the ability to acquire data at 20K samples/second/channel, the EX1401 can be deployed in situations that demand rapid responses to quickly changing conditions, including high-speed temperature transient applications. The EX1401 has application in automotive and battery testing; highly accelerated life test/ highly accelerated stress screening (HALT/HASS); health monitoring; and jet engine testing. It can be used in any test environment that requires accurate temperature measurement and repeatability.

An industry-standard LXI interface allows the EX1401 to be distributed and positioned close to the device-under-test, reducing the implementation and support costs associated with long cable lengths. That also reduces transducer cable lengths and associated coupled EMI interference, helping improve measurement accuracy. In addition, the instrument features a comprehensive, built-in self-test function that reports instrument status and problems, maximizing run-time performance.

A full-featured embedded web interface provides configuration and data displays, simplifying setup and usage. EXLab Express, VTI’s intuitive data acquisition software, is included with each instrument, eliminating the need for programming.

Parallel data storage and standalone autonomous operating modes further expand the utility of this versatile instrument. The EX1401 also supports IEEE 1588 Precision Time Protocol (PTP), allowing engineers to synchronize measurements from many devices throughout the test application.

Features at a Glance

  • Typical accuracies of ±0.20°C
  • 16-channel isolated universal thermocouple/voltage inputs
  • Power over Ethernet+ (PoE+)
  • 20K samples/second/channel sample rate
  • 24-bit ADC per channel
  • 500 V channel-ground isolation
  • 1000 V channel-channel isolation
  • Data logger acquisition mode
  • Built-in parallel data streaming
  • Full-featured embedded web interface
  • LXI Ethernet interface
  • 8-bit bank isolated digital I/O
  • Compact 1U half-rack form factor

AMETEK VTI Instruments

www.vtiinstruments.com

Filed Under: Test and Measurement News Tagged With: vtiinstruments

Reader Interactions

Leave a Reply Cancel reply

You must be logged in to post a comment.

Primary Sidebar

Featured Contributions

Why engineers need IC ESD and TLP data

Verify, test, and troubleshoot 5G Wi-Fi FWA gateways

How to build and manage a top-notch test team

How to use remote sensing for DC programmable power supplies

The factors of accurate measurements

More Featured Contributions

EE TECH TOOLBOX

“ee
Tech Toolbox: Test & Measurement
We’ve gathered articles that include hands-on product tryouts and reviews. Indeed, every article in this issue uses an oscilloscope in one way or another so you might just call this “The Oscilloscope Tech Toolbox.”

EE TRAINING CENTER

EE Learning Center
“test
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for EE professionals.
bills blog

RSS Current Electro-Tech-Online.com Discussions

  • Quick question on capacitors value in UF
  • EEPROM not being written or read on dsPIC30F2010
  • Want Thermal Camera with Fixed Thermal Span option
  • Printer loop
  • mechanism to shutdown feeding when sensor temperature rises

Footer

EE World Online Network

  • 5G Technology World
  • EE World Online
  • Engineers Garage
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • EDA Board Forums
  • Electro Tech Online Forums
  • EV Engineering
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips

Test & Measurement Tips

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us

Copyright © 2025 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy