• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
  • Advertise
  • Subscribe

Test & Measurement Tips

Oscilloscopes, electronics engineering industry news, how-to EE articles and electronics resources

  • Oscilloscopes
    • Analog Oscilloscope
    • Digital Oscilloscope
    • Handheld Oscilloscope
    • Mixed-signal Oscilloscope
    • PC-based Oscilloscopes – PCO
  • Design
  • Calibration
  • Meters & Testers
  • Test Equipment
  • Learn
    • eBooks/Tech Tips
    • FAQs
    • EE Training Days
    • Learning Center
    • Tech Toolboxes
    • Webinars & Digital Events
  • Video
    • EE Videos
    • Teardown Videos
  • Resources
    • Design Guide Library
    • Digital Issues
    • Engineering Diversity & Inclusion
    • Leap Awards
    • White Papers
  • Subscribe
You are here: Home / Meters & Testers / High-performance LCR meter spans 4 Hz to 10 MHz range

High-performance LCR meter spans 4 Hz to 10 MHz range

March 15, 2022 By Lee Teschler Leave a Comment

The R&S LCX family of LCR meters serves all established impedance measurements plus specialized measurements for selected component types and provides both, the high accuracy required in R&D, and the high speed needed in production test and quality assurance.

With its supported frequency range from 4 Hz to 10 MHz, the R&S LCX is suitable not only for the vast majority of rohde&schwarz LCRdevices operating at conventional 50 or 60 Hz domestic power frequencies or 400 Hz for aircraft, but also for everything from low frequency seismic sensors to high power communication circuits operating at several Megahertz.

For engineers selecting suitable capacitors, inductances, resistors, and analog filters to match the device application, the R&S LCX models provide high precision impedance values with market-leading accuracy. Equally, higher speed measurements at production-use accuracy for quality control and monitoring are also supported. All the essential software and hardware required for production environments is available, including remote control and result logging, as well as rack mounting for the instrument, and a full range of test fixtures for handling components.

The auto-balancing bridge technology used by the R&S LCX supports conventional impedance measurements by measuring the ac voltage and current for the device under test, including the phase shift. This is then used to calculate complex impedance at any given operational point. As a general purpose LCR meter, the R&S LCX covers many applications, such as the measurement of equivalent series resistance (ESR) and equivalent series inductance (ESL) of electrolytic capacitors and dc-link capacitors. Furthermore, users can test transformers and measure dc resistance in addition to the full range of impedance measurements. To investigate components with impedance values varying at different frequencies and levels, option R&S LCX-K106 supports dynamic impedance measurements with the frequency, voltage or current as the swept parameter.

The R&S LCX family is launched with two models; the R&S LCX100 covers a frequency range from 4 Hz to 300 kHz, the R&S LCX200 a basic frequency range from 4 Hz to 500 kHz with options to cover all frequencies up to 10 MHz. Both models feature a large capacitive touchscreen and virtual keyboard to support tap-and-test for all main measurements. Alternatively, voltage, current, and frequency values can be set using the rotary knob. Less frequently used functions are menu-operated. Settings, results, and statistics can be displayed on the screen or output for automated post-processing. Up to four measurements can be selected and plotted versus time, with minimum and maximum values included in the display for at-a-glance pass/fail analysis.

Rohde & Schwarz USA, Inc., 6821 Benjamin Franklin Dr, Columbia, MD 21046, www.rohde-schwarz.com/product/lcx.

You may also like:

  • music on scopes
    Making pictures from sound on an oscilloscope
  • Havana syndrome
    Microwaves and the Havana Syndrome
  • 5G
    Will 5G be lethal?
  • rental instruments
    The modern economics of renting test instruments
  • no you can't detect ghosts with a gauss meter
    No, you can’t detect ghosts with a gauss meter

Filed Under: Meters & Testers, New Articles, Test Equipment Tagged With: rohdeschwarz

Reader Interactions

Leave a Reply Cancel reply

You must be logged in to post a comment.

Primary Sidebar

Featured Contributions

Why engineers need IC ESD and TLP data

Verify, test, and troubleshoot 5G Wi-Fi FWA gateways

How to build and manage a top-notch test team

How to use remote sensing for DC programmable power supplies

The factors of accurate measurements

More Featured Contributions

EE TECH TOOLBOX

“ee
Tech Toolbox: Test & Measurement
We’ve gathered articles that include hands-on product tryouts and reviews. Indeed, every article in this issue uses an oscilloscope in one way or another so you might just call this “The Oscilloscope Tech Toolbox.”

EE TRAINING CENTER

EE Learning Center
“test
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for EE professionals.
bills blog

RSS Current Electro-Tech-Online.com Discussions

  • Quick question on capacitors value in UF
  • EEPROM not being written or read on dsPIC30F2010
  • Want Thermal Camera with Fixed Thermal Span option
  • Printer loop
  • mechanism to shutdown feeding when sensor temperature rises

Footer

EE World Online Network

  • 5G Technology World
  • EE World Online
  • Engineers Garage
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • EDA Board Forums
  • Electro Tech Online Forums
  • EV Engineering
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips

Test & Measurement Tips

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us

Copyright © 2025 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy