• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
  • Advertise
  • Subscribe

Test & Measurement Tips

Oscilloscopes, electronics engineering industry news, how-to EE articles and electronics resources

  • Oscilloscopes
    • Analog Oscilloscope
    • Digital Oscilloscope
    • Handheld Oscilloscope
    • Mixed-signal Oscilloscope
    • PC-based Oscilloscopes – PCO
  • Design
  • Calibration
  • Meters & Testers
  • Test Equipment
  • Learn
    • eBooks/Tech Tips
    • FAQs
    • EE Training Days
    • Learning Center
    • Tech Toolboxes
    • Webinars & Digital Events
  • Video
    • EE Videos
    • Teardown Videos
  • Resources
    • Design Guide Library
    • Digital Issues
    • Engineering Diversity & Inclusion
    • Leap Awards
    • White Papers
  • Subscribe
You are here: Home / Featured / Should I use a spectrum analyzer, signal analyzer, or vector network analyzer? Part 4

Should I use a spectrum analyzer, signal analyzer, or vector network analyzer? Part 4

August 19, 2024 By Rick Nelson Leave a Comment

A vector network analyzer can fully characterize components by deriving their scattering parameters.

siglent vna
Siglent Technologies VNA

In earlier parts of this series, we looked at analog spectrum analyzers (part 1 and part 2) and vector signal analyzers (part 3), both of which monitor unknown signals, whether emanating from a system, device under test (DUT), or an enemy’s transmitter in an electronic-warfare scenario. Yet another analyzer is the vector network analyzer (VNA). Unlike the other analyzers, it comes with its own variable-frequency signal generator, and it determines how a DUT responds to the signals it generates.

How does it work?

In Figure 1, the VNA source drives a splitter, which divides the signal into two equal parts. One part goes to a reference-receiver input (labeled Ref), and the other, labeled a1, goes to the DUT’s port 1 (P1). A portion of that signal (b2) will emerge from the DUT’s port 2 (P2) and be transmitted to a load, typically equal to the test system’s characteristic impedance Z0. From an earlier post on insertion loss and return loss, we know that DUT impedance mismatches will cause some portion of the signal to reflect back toward the source (b1). Directional couplers DC1 and DC2 connect the reflected and transmitted signals b1 and b2, respectively, to the VNA’s test receivers T1 and T2, and the VNA calculates the DUT’s scattering-parameter (S-parameter) matrix and displays the results, often in the form of a Smith chart, which we looked at in an earlier series.

VNA diagram
Figure 1. A VNA applies an incident signal (blue) to a DUT and measures the transmitted (red) and reflected (orange) signals.

Why S-parameters, not voltages, currents, and impedances?

Voltage and current are difficult to measure at high frequencies. Figure 2 helps illustrate why. At the top, we have a DC circuit with point sources and loads and ideal wires, and we can locate our voltmeters and ammeters at various locations and still get consistent readings. Granted, real wires can have IR drops at high currents and long lead lengths, but we can compensate using, for example, a four-wire measurement technique that adds the sense wires shown in red.

VNA S-paramater ports
Figure 2. Meters distributed throughout a DC circuit provide consistent results (top), but that’s not the case for high-frequency circuits (bottom).

At high frequencies, the situation is completely different. As shown at the bottom, our wires are infinite series of infinitely small impedance elements, and measurement results depend on where we make the measurements. Cables are often shielded, but even if we could penetrate the shield to connect voltmeters or ammeters, we wouldn’t know exactly where to probe, and the meter leads would become stubs that degrade the signal we are trying to measure. What we can do is accurately measure power at cable connectors and device ports. S-parameters are simply ratios of power measurements.

How are the S-parameters calculated?
For the Figure 1 setup, the calculation proceeds as follows:

Insert Eq1 here

where s11¬ equals the reflection coefficient and s21 equals the transmission coefficient.

Figure 3 illustrates a point about S-parameter notation. Counterintuitively, the first digit of the subscript refers to the DUT port from which energy emanates, and the second digit refers to the port to which energy is applied.

Figure 3. S-parameter notation can be counterintuitive.

Do the two S-parameters completely characterize our DUT?
No. The number of S-parameters for an n-port network is n2, so our two-port network has four S-parameters. We could simply turn the DUT around to measure the other two, but that’s error-prone and inconvenient, requiring recalibration. Alternatively, we can choose a VNA configured as shown in Figure 4, where a switch reroutes the signal-source output (a2) to P2. (Additional poles of the switch connect and disconnect load Z0 as required.) Then, DC1 and DC2 route the transmitted (b1) and reflected (b2) signals to the VNA receivers, and the VNA calculates the remaining two S-parameters.

VNA switch port
Figure 4. A switch connects the source to P2.

Figure 5 shows a simplified diagram of the forward and reverse paths through the DUT along with the full set of four S-parameters, where s22¬ and s¬12 represent the reverse reflection coefficient and reverse transmission coefficient, respectively.

VNA two-port network
Figure 5. A two-port network has four S-parameters, representing forward and reverse reflected and transmitted signals.

How many ports can a VNA have?

Rohde & Schzwarz 24-port VNA

You can buy a one-port VNA. Often called a reflectometer, it measures s11. There is no theoretical upper limit to the number of ports. Versions configured with 24 ports are commercially available, and you can use RF switching matrices to add ports to a VNA you already have.

Do VNAs have applications outside of electronics?
Yes, VNAs find use in applications ranging from healthcare to agriculture.

Where can I learn more?
See these resources:

  • Understanding Vector Network Analysis (Anritsu)
  • Using a VNA to Measure Soil Moisture Levels (Copper Mountain Technologies)
  • Understanding the Fundamental Principles of Vector Network Analysis (Keysight)
  • Rapid Characterization of High Speed Digital Channels using a Multiport VNA (Rohde & Schwarz)
  • What is a Vector Network Analyzer and How Does it Work? (Tektronix)

You may also like:


  • Should I use a spectrum, signal, or vector network analyzer?…

  • Should I use a spectrum, signal, or vector network analyzer?…

  • IMS 2024 roundup: test equipment

  • Should I use a spectrum, signal, or vector network analyzer?…

  • New products at the EMC & Compliance International Conference

  • How to measure PCB trace or power/return plane impedance

  • IMS 2023 roundup: test equipment

Filed Under: FAQ, Featured, vector network analyzer, wireless test equipment Tagged With: rohdeschwarz, siglenttechnologies, Signal Analyzer, spectrum analyzer, vector network analyzer

Reader Interactions

Leave a Reply Cancel reply

You must be logged in to post a comment.

Primary Sidebar

Featured Contributions

Why engineers need IC ESD and TLP data

Verify, test, and troubleshoot 5G Wi-Fi FWA gateways

How to build and manage a top-notch test team

How to use remote sensing for DC programmable power supplies

The factors of accurate measurements

More Featured Contributions

EE TECH TOOLBOX

“ee
Tech Toolbox: Internet of Things
Explore practical strategies for minimizing attack surfaces, managing memory efficiently, and securing firmware. Download now to ensure your IoT implementations remain secure, efficient, and future-ready.

EE TRAINING CENTER

EE Learning Center

EE ENGINEERING TRAINING DAYS

engineering
“test
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for EE professionals.
“bills

RSS Current EDABoard.com discussions

  • Is it possible to improve accuarcy of ad633
  • 12VAC to 12VDC 5A on 250ft 12AWG
  • Battery sensing circuitry for coin cell application
  • Copper Pour Support in Altium Softwarez
  • Input impedance matching network

RSS Current Electro-Tech-Online.com Discussions

  • Telegram Based Alarm - Sensor cable protection
  • Chinese Tarrifs – 104%!?!
  • An Update On Tarrifs
  • Tariff Updates from JLCPCB as of Today
  • Solar lighting motion detector
Search Millions of Parts from Thousands of Suppliers.

Search Now!
design fast globle

Footer

EE World Online Network

  • 5G Technology World
  • EE World Online
  • Engineers Garage
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • DesignFast
  • EDA Board Forums
  • Electro Tech Online Forums
  • EV Engineering
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips

Test & Measurement Tips

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us

Copyright © 2025 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy