• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
  • Advertise
  • Subscribe

Test & Measurement Tips

Oscilloscopes, electronics engineering industry news, how-to EE articles and electronics resources

  • Oscilloscopes
    • Analog Oscilloscope
    • Digital Oscilloscope
    • Handheld Oscilloscope
    • Mixed-signal Oscilloscope
    • PC-based Oscilloscopes – PCO
  • Design
  • Calibration
  • Meters & Testers
  • Test Equipment
  • Learn
    • eBooks/Tech Tips
    • FAQs
    • EE Training Days
    • Learning Center
    • Tech Toolboxes
    • Webinars & Digital Events
  • Video
    • EE Videos
    • Teardown Videos
  • Resources
    • Design Guide Library
    • Digital Issues
    • Engineering Diversity & Inclusion
    • Leap Awards
    • White Papers
  • Subscribe
You are here: Home / Calibration / Traceability and the hierarchy of calibration

Traceability and the hierarchy of calibration

October 31, 2022 By Michael Brown Leave a Comment

Advances in the science of measurement are simplifying the task of accurately quantifying uncertainty.

Michael Brown, Fluke Calibration
Accurate measurements are critical to every aspect of our lives; that’s why metrology is the oldest science in the world. Our ability to understand the world around us depends on how well we can measure it.

fluke SI hierarchy
The calibration universe creates a way for the SI to be passed down the calibration pyramid into the industry.
As time and technology have advanced, so too have metrology and the science of measurement. Each advance in metrology also requires a look back. Any calibrations or new measurement technologies must be compared against the International System of Units (SI). Until recently, these standards for comparisons were specially constructed physical artifacts that represented each measurement discipline. For example, the kilogram artifact was a cylinder of platinum-iridium alloy about the size of a plum. But in 2018, the SI was revised to base the measurements on constants of nature.

Why the change? Many of the artifacts were carefully kept under lock and key so they didn’t erode. Over the centuries, the materials used could change, erode, or become inaccurate which would throw off measurements down the line. That was just a level of uncertainty we all had to live with, making scientists unhappy for many years. But that uncertainty has vanished with the adoption of natural constants.

The change in standards practices involves the hierarchy of calibration and why it exists. Of course, ordinary technical personnel can’t directly check their

fluke calibrator
The Fluke Calibration 5080A High Compliance Multi-Product Calibrator calibrates a digital multimeter.
measurements against the measurement artifacts such as those stored at NIST. In the new SI many of the items needed to realize the new constants of nature in a laboratory are not readily available to all, or are cost prohibitive and large. So, not every measurement can be compared against these standards to ensure it’s accuracy. Instead, we rely on a sequence of calibrations all leading back to the SI. Every instrument used in the lineup has a spot on the hierarchy with the SI sitting at the top.

For example, a digital multimeter is calibrated by a multifunction calibrator. That multifunction calibrator was calibrated by a more accurate multi-product bench calibrator in a calibration lab. In turn, that bench calibrator was calibrated by even more accurate references in one of the National Metrology Institutes (NMI). And finally the references used in the NMI have been compared against the SI to determine their accuracy.

The necessity of traceability

Traceability documents the measurement hierarchy. The traceability pyramid creates an efficient and economic way for each lab or individual to access calibration standards. The series of tools and calibrators comprising the pyramid to the SI helps demonstrate the uncertainty level for each tool’s accuracy. Traceability steps form a chain of calibrations from the SI on down.

fluke calibrator
Fluke Calibration 8558A 8.5 Digit Multimeter can be used to calibrate a multifunction calibrator.
Below the SI sits National Metrology Institutes (NMI), the group that facilitates the promotion of the SI. However, every lab or individual can’t work directly with the NMIs. NMI-level calibration standards are used to calibrate primary calibration standards or instruments. Those primary calibration standards are then used to calibrate secondary standards. Those are then used to calibrate working standards. Each of these levels allows efficient and affordable dissemination of SI standards down the calibration chain.

The process of keeping traceability records is important for metrology as a whole, but also within industries. Many technical and quality industry standards require proof of the unbroken chain back to the pertinent SI unit.

The paper-based recording process has been cumbersome. As a tool is calibrated, the lab doing the work would print out a calibration certificate showing what was calibrated and how it was calibrated. This certificate would often include a statement of traceability or a list of calibration standards used for that particular calibration. The downside of this process was that each lab had their own way of recording calibration data. The calibration statement could vary from one lab to another–not all calibrations laboratories followed the same industry standards or fit in the same place on the calibration hierarchy.

As nearly everything is becoming digital, so too is traceability. By digitizing the calibration certificates, industry can have a database of traceability for each instrument. The traceability pyramid can become a digital calibration chain, containing information about measurements on the tools, as well as those above, below, or around them. The digitization of calibration certificates, in addition to the refreshed SI constants, brings the world one step closer to realizing the “for all times, for all people” idea behind the original SI.

You may also like:


  • Gallery: Technology on display at Automotive Testing Expo 2022
  • calibration
    What to look for during instrument calibration
  • frequency you can count on
    Will 60 Hz continue to be a frequency you can…

  • June 2022 Special Edition: Test & Measurement Handbook
  • Havana syndrome
    Microwaves and the Havana Syndrome

Filed Under: Calibration, FAQ, Featured, Featured Contributions Tagged With: FAQ, flukecalibration

Reader Interactions

Leave a Reply Cancel reply

You must be logged in to post a comment.

Primary Sidebar

Featured Contributions

Why engineers need IC ESD and TLP data

Verify, test, and troubleshoot 5G Wi-Fi FWA gateways

How to build and manage a top-notch test team

How to use remote sensing for DC programmable power supplies

The factors of accurate measurements

More Featured Contributions

EE TECH TOOLBOX

“ee
Tech Toolbox: Power Efficiency
Discover proven strategies for power conversion, wide bandgap devices, and motor control — balancing performance, cost, and sustainability across industrial, automotive, and IoT systems.

EE TRAINING CENTER

EE Learning Center
“test
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for EE professionals.
bills blog

RSS Current Electro-Tech-Online.com Discussions

  • ESP32-S3 started outputting NMEA GPS location frames after EMC disturbance — what mode is this?
  • TraxMaker Pro? I only have the non-Pro version. Looking for the Pro version that has the integrated pick and place coordinates export.
  • Can a small solar panel safely trickle-charge old NiMH AA batteries?
  • desoldering
  • Need a fresh eye on my first PCB

Footer

EE World Online Network

  • 5G Technology World
  • EE World Online
  • Engineers Garage
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • EDA Board Forums
  • Electro Tech Online Forums
  • EV Engineering
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips

Test & Measurement Tips

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us

Copyright © 2025 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy