• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
  • Advertise
  • Subscribe

Test & Measurement Tips

Oscilloscopes, electronics engineering industry news, how-to EE articles and electronics resources

  • Oscilloscopes
    • Analog Oscilloscope
    • Digital Oscilloscope
    • Handheld Oscilloscope
    • Mixed-signal Oscilloscope
    • PC-based Oscilloscopes – PCO
  • Design
  • Calibration
  • Meters & Testers
  • Test Equipment
  • Learn
    • eBooks/Tech Tips
    • FAQs
    • EE Training Days
    • Learning Center
    • Tech Toolboxes
    • Webinars & Digital Events
  • Video
    • EE Videos
    • Teardown Videos
  • Resources
    • Design Guide Library
    • Digital Issues
    • Engineering Diversity & Inclusion
    • Leap Awards
    • White Papers
  • Subscribe
You are here: Home / Oscilloscopes / Software for the DCA-X Oscilloscope by Agilent

Software for the DCA-X Oscilloscope by Agilent

June 28, 2012 By Test and Measurement Editor Leave a Comment

Agilent N1012A compliance test software is the industry’s first automated application for the Optical Internetworking Forum’s Common Electrical Interface (OIF CEI) 3.0 Implementation Agreement. The N1012A has two new test applications that leverage the high bandwidth and low jitter performance of the Infiniium 86100D DCA-X oscilloscope. The user-defined application enables engineers to rapidly develop their own automated test applications. Both software packages help developers save time and money.

Using multiple lanes at 25 to 28 Gb/s, these high data rates increase the importance of flawless equipment interoperability, which necessitates more extensive equipment testing and stringent test limits. The Implementation Agreement covers eight interfaces with nearly 120 tests. Several other standards also address tests at these data rates.

The compliance software performs a wide range of oscilloscope-based and network analyzer-based tests for the Implementation Agreement. The software also provides 5 to 28 Gb/s physical-layer transmitter measurements for engineers designing to the requirements of OIF CEI 3.0.

The user-defined application expands the capability of the existing N5467A user-defined application to include the 86100D DCA-X. Users can create their own tests, automated test groups, test limits with descriptions, measurement configurations, and customized reports.

The new applications for 86100D DCA-X oscilloscope provide design and validation engineers with a fast and easy way to verify physical-layer transmitter compliance to the appropriate standards.

Agilent N1012A compliance test software:

  • Provides automation of the nearly 120 tests in the OIF-CEI 3.0 agreement, including eye, waveform, jitter, return loss and resistance tests.
  • Supports use of Agilent’s 86108B precision waveform analyzer, other dual-electrical receivers, clock recovery and precision timebase products, and Agilent’s precision network analyzer family.
  • Enables fast de-skew of cables and automatic determination of optimal peaking values for continuous time linear equalization.
  • Displays the results in a flexible report format.
  • Provides a margin analysis that shows how closely a device passes or fails each test.

The Agilent N1019A user-defined application:

  • Enables fast creation of multiple tests on the 86100D DCA-X oscilloscope and other equipment.
  • Takes full advantage of the SCPI recorder feature within the FlexDCA interface.
  • Supports interfacing with the device under test for sequencing and control.
  • Enables testing against compliance limits and reporting of pass/fail margins.
  • Displays results in a flexible report format.

Agilent
www.agilent.com

Filed Under: Oscilloscopes Tagged With: Agilent Technologies, oscilloscope

Reader Interactions

Leave a Reply Cancel reply

You must be logged in to post a comment.

Primary Sidebar

Featured Contributions

Why engineers need IC ESD and TLP data

Verify, test, and troubleshoot 5G Wi-Fi FWA gateways

How to build and manage a top-notch test team

How to use remote sensing for DC programmable power supplies

The factors of accurate measurements

More Featured Contributions

EE TECH TOOLBOX

“ee
Tech Toolbox: Internet of Things
Explore practical strategies for minimizing attack surfaces, managing memory efficiently, and securing firmware. Download now to ensure your IoT implementations remain secure, efficient, and future-ready.

EE TRAINING CENTER

EE Learning Center

EE ENGINEERING TRAINING DAYS

engineering
“test
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for EE professionals.
“bills

RSS Current EDABoard.com discussions

  • Editing posts
  • Help Creating .lib File for SCR in LTspice
  • About IF transformers.
  • Bidirectional data bus
  • ISL8117 buck converter blowing up

RSS Current Electro-Tech-Online.com Discussions

  • RS485 bus: common ground wire needed or not?
  • Kawai KDP 80 Electronic Piano Dead
  • Good Eats
  • What part is this marked .AC ?
  • Photo interrupter Connections
Search Millions of Parts from Thousands of Suppliers.

Search Now!
design fast globle

Footer

EE World Online Network

  • 5G Technology World
  • EE World Online
  • Engineers Garage
  • Analog IC Tips
  • Battery Power Tips
  • Connector Tips
  • DesignFast
  • EDA Board Forums
  • Electro Tech Online Forums
  • EV Engineering
  • Microcontroller Tips
  • Power Electronic Tips
  • Sensor Tips

Test & Measurement Tips

  • Subscribe to our newsletter
  • Advertise with us
  • Contact us
  • About us

Copyright © 2025 · WTWH Media LLC and its licensors. All rights reserved.
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media.

Privacy Policy